119 research outputs found

    Brazilian gamma detection device for sentinel lymph node biopsy

    Get PDF
    OBJECTIVE: To test the effectiveness of an intra-operative gamma detection Brazilian device (IPEN) on sentinel lymph node biopsy (SLNB) procedures. METHODS: Forty melanoma or breast cancer patients with indication for undergoing SLNB were studied. Lymphoscintigraphy was done 2 to 24 hours prior to surgery. Lymphatic mapping with vital dye and gamma detection were performed intraoperatively. For gamma detection Neoprobe ® 1500 was used followed by IPEN (equipment under test) in the first 20 patients and for the remaining half IPEN was used first to verify its ability to locate the sentinel node (SN). Measurements were taken from the radiopharmaceutical product injection site, from SN (in vivo and ex vivo) and from background. It was recorded if the SN was stained or not and if it was found easily by surgeon. RESULTS: There were 33 (82.5%) breast cancer and 7 (17.5%) melanoma patients. Ages varied from 21 to 68 year-old (median age of 46). Sex distribution was 35 (87.5%) women and 5 (12.5%) men. Sentinel node was found in all but one patient. There was no statistical difference between the reasons ex vivo/ background obtained with the measures of both equipments (p=0, 2583-ns). The SN was easily found by the surgeon with both devices. CONCLUSION: The SLNB was successfully performed using either equipment. It was possible to do SLNB with the Brazilian device developed by IPEN without prejudice for the patient.OBJETIVO: Testar a eficácia de equipamento de detecção gama intra-operatória (DGI) desenvolvido pelo IPEN (Brasil), em procedimentos de biópsia de linfonodo sentinela (BLS) no melanoma e no câncer de mama. MÉTODOS: Foram estudados 40 pacientes portadores de melanoma ou câncer de mama com indicação para realização de BLS.Todos pacientes foram submetidos à linfocintilografia e a BLS ocorreu entre 2 a 24 horas após a mesma. Concomitantemente à DGI, realizou-se o mapeamento linfático com corante vital. Foram feitas leituras com o equipamento convencional Neoprobe® 1500 e com o equipamento em teste (IPEN) dos valores de captação do sítio de injeção do radiofármaco, do LS in vivo e ex vivo e da captação de fundo. Foi registrado se o LS estava corado e se o cirurgião teve facilidade para encontrá-lo. Nos primeiros 20 pacientes utilizou-se o equipamento convencional e depois o de teste; nos outros 20, utilizou-se primeiro o equipamento em teste, com objetivo de verificar se o mesmo identificava primariamente o LS. RESULTADOS: Dos quarenta pacientes, 33 eram portadores de tumor de mama e sete de melanoma cutâneo; variação da idade: 21 a 68 anos (mediana= 46 anos); 35 mulheres e 5 homens. Em apenas um paciente o LS não foi encontrado, nem pela DGI nem pelo corante vital. Não houve diferença estatística entre as razões ex vivo/fundo obtidas com os dois equipamentos (p=0, 2583-ns). CONCLUSÃO: É possível realizar o procedimento de BLS com o equipamento brasileiro desenvolvido pelo IPEN, com facilidade e sem prejuízo para o paciente.Hospital Israelita Albert EinsteinIPENUniversidade Federal de São Paulo (UNIFESP)Faculdade de Medicina Anhembi-MorumbiUNIFESPSciEL

    Maternal microchimerism in the livers of patients with Biliary atresia

    Get PDF
    BACKGROUND: Biliary atresia (BA) is a neonatal cholestatic disease of unknown etiology. It is the leading cause of liver transplantation in children. Many similarities exist between BA and graft versus host disease suggesting engraftment of maternal cells during gestation could result in immune responses that lead to BA. The aim of this study was to determine the presence and extent of maternal microchimerism (MM) in the livers of infants with BA. METHODS: Using fluorescent in situ hybridization (FISH), 11 male BA & 4 male neonatal hepatitis (NH) livers, which served as controls, were analyzed for X and Y-chromosomes. To further investigate MM in BA, 3 patients with BA, and their mothers, were HLA typed. Using immunohistochemical stains, the BA livers were examined for MM. Four additional BA livers underwent analysis by polymerase chain reaction (PCR) for evidence of MM. RESULTS: By FISH, 8 BA and 2 NH livers were interpretable. Seven of eight BA specimens showed evidence of MM. The number of maternal cells ranged from 2–4 maternal cells per biopsy slide. Neither NH specimen showed evidence of MM. In addition, immunohistochemical stains confirmed evidence of MM. Using PCR, a range of 1–142 copies of maternal DNA per 25,000 copies of patients DNA was found. CONCLUSIONS: Maternal microchimerism is present in the livers of patients with BA and may contribute to the pathogenesis of BA

    Inhibition of platelet aggregation by carbon monoxide-releasing molecules (CO-RMs): comparison with NO donors

    Get PDF
    Carbon monoxide (CO) and CO-releasing molecules (CO-RMs) inhibit platelet aggregation in vitro. Herein, we compare the anti-platelet action of CORM-3, which releases CO rapidly (t½ 1 min), and CORM-A1, which slowly releases CO (t½ = 21 min). The anti-platelet effects of NO donors with various kinetics of NO release were studied for comparison. The effects of CO-RMs and NO donors were analyzed in washed human platelets (WP), platelets rich plasma (PRP), or whole blood (WB) using aggregometry technique. CORM-3 and CORM-A1 inhibited platelet aggregation in human PRP, WP, or WB, in a concentration-dependent manner. In all three preparations, CORM-A1 was more potent than CORM-3. Inhibition of platelets aggregation by CORM-A1 was not significantly affected by a guanylate cyclase inhibitor (ODQ) and a phosphodiesterase-5 inhibitor, sildenafil. In contrast, inhibition of platelet aggregation by NO donors was more potent with a fast NO releaser (DEA-NO, t½ = 2 min) than slow NO releasers such as PAPA-NO (t½ = 15 min) or other slow NO donors. Predictably, the anti-platelet effect of DEA-NO and other NO donors was reversed by ODQ while potentiated by sildenafil. In contrast to NO donors which inhibit platelets proportionally to the kinetics of NO released via activation of soluble guanylate cyclase (sGC), the slow CO-releaser CORM-A1 is a superior anti-platelet agent as compared to CORM-3 which releases CO instantly. The anti-platelet action of CO-RMs does not involve sGC activation. Importantly, CORM-A1 or its derivatives representing the class of slow CO releasers display promising pharmacological profile as anti-platelet agents

    Isoflurane Preconditioning at Clinically Relevant Doses Induce Protective Effects of Heme Oxygenase-1 on Hepatic Ischemia Reperfusion in Rats

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Activation of heme oxygenase-1 (HO-1) has been proved to reduce damages to the liver in ischemia reperfusion injury. The objective of present study was to determine whether clinic relevant doses of isoflurane treatment could be sufficient to activate HO-1 inducing, which confers protective effect against hepatic ischemia-reperfusion injury.</p> <p>Methods</p> <p>The hepatic artery and portal vein to the left and the median liver lobes of forty male Sprague-Dawley rats were occluded for 60 minutes. Reperfusion was allowed for 4 hours before the animal subjects were sacrificed. Six groups (n = 12) were included in the study. A negative control group received sham operation and positive control group a standard ischemia-reperfusion regimen. The third group was pretreated with isoflurane prior to the ischemia-reperfusion. The fourth group received an HO-1 inhibitor zinc protoporphyrin (Znpp) prior to the isoflurane pretreatment and the ischemia-reperfusion. The fifth group received Znpp alone before ischemia-reperfusion procedure, and the sixth group was administrated with a HO-1 inducer hemin prior to IR. HO-1 in the liver was measured using an enzymatic activity assay, a Western blot analysis, as well as immunohistochemical method. Extent of liver damage was estimated by determination of the serum transaminases, liver lipid peroxidation and hepatic histology. Infiltration of the liver by neutrophils was measured using a myeloperoxidase activity assay. TNFα mRNA in the liver was measured using RT-PCR.</p> <p>Results</p> <p>Isoflurane pretreatment significantly attenuated the hepatic injuries and inflammatory responses caused by the ischemia reperfusion. Selectively inhibiting HO-1 with ZnPP completed blocked the protective effects of isoflurane. Inducing HO-1 with hemin alone produced protective effects similar in magnitude to that of isoflurane.</p> <p>Conclusions</p> <p>Clinic relevant doses of isoflurane attenuate ischemia reperfusion injury in rats by increasing the HO-1 expression and activity.</p

    Carbon monoxide-Releasing Molecule-2 (CORM-2) attenuates acute hepatic ischemia reperfusion injury in rats

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hepatic ischemia-reperfusion injury (I/Ri) is a serious complication occurring during liver surgery that may lead to liver failure. Hepatic I/Ri induces formation of reactive oxygen species, hepatocyte apoptosis, and release of pro-inflammatory cytokines, which together causes liver damage and organ dysfunction. A potential strategy to alleviate hepatic I/Ri is to exploit the potent anti-inflammatory and cytoprotective effects of carbon monoxide (CO) by application of so-called CO-releasing molecules (CORMs). Here, we assessed whether CO released from CORM-2 protects against hepatic I/Ri in a rat model.</p> <p>Methods</p> <p>Forty male Wistar rats were randomly assigned into four groups (n = 10). Sham group underwent a sham operation and received saline. I/R group underwent hepatic I/R procedure by partial clamping of portal structures to the left and median lobes with a microvascular clip for 60 minutes, yielding ~70% hepatic ischemia and subsequently received saline. CORM-2 group underwent the same procedure and received 8 mg/kg of CORM-2 at time of reperfusion. iCORM-2 group underwent the same procedure and received iCORM-2 (8 mg/kg), which does not release CO. Therapeutic effects of CORM-2 on hepatic I/Ri was assessed by measuring serum damage markers AST and ALT, liver histology score, TUNEL-scoring of apoptotic cells, NFkB-activity in nuclear liver extracts, serum levels of pro-inflammatory cytokines TNF-α and IL-6, and hepatic neutrophil infiltration.</p> <p>Results</p> <p>A single systemic infusion with CORM-2 protected the liver from I/Ri as evidenced by a reduction in serum AST/ALT levels and an improved liver histology score. Treatment with CORM-2 also up-regulated expression of the anti-apoptotic protein Bcl-2, down-regulated caspase-3 activation, and significantly reduced the levels of apoptosis after I/Ri. Furthermore, treatment with CORM-2 significantly inhibited the activity of the pro-inflammatory transcription factor NF-κB as measured in nuclear extracts of liver homogenates. Moreover, CORM-2 treatment resulted in reduced serum levels of pro-inflammatory cytokines TNF-α and IL-6 and down-regulation of the adhesion molecule ICAM-1 in the endothelial cells of liver. In line with these findings, CORM-2 treatment reduced the accumulation of neutrophils in the liver upon I/Ri. Similar treatment with an inactive variant of CORM-2 (iCORM-2) did not have any beneficial effect on the extent of liver I/Ri.</p> <p>Conclusions</p> <p>CORM-2 treatment at the time of reperfusion had several distinct beneficial effects on severity of hepatic I/Ri that may be of therapeutic value for the prevention of tissue damage as a result of I/Ri during hepatic surgery.</p

    Contraindications of sentinel lymph node biopsy: Áre there any really?

    Get PDF
    BACKGROUND: One of the most exciting and talked about new surgical techniques in breast cancer surgery is the sentinel lymph node biopsy. It is an alternative procedure to standard axillary lymph node dissection, which makes possible less invasive surgery and side effects for patients with early breast cancer that wouldn't benefit further from axillary lymph node clearance. Sentinel lymph node biopsy helps to accurately evaluate the status of the axilla and the extent of disease, but also determines appropriate adjuvant treatment and long-term follow-up. However, like all surgical procedures, the sentinel lymph node biopsy is not appropriate for each and every patient. METHODS: In this article we review the absolute and relative contraindications of the procedure in respect to clinically positive axilla, neoadjuvant therapy, tumor size, multicentric and multifocal disease, in situ carcinoma, pregnancy, age, body-mass index, allergies to dye and/or radio colloid and prior breast and/or axillary surgery. RESULTS: Certain conditions involving host factors and tumor biologic characteristics may have a negative impact on the success rate and accuracy of the procedure. The overall fraction of patients unsuitable or with multiple risk factors that may compromise the success of the sentinel lymph node biopsy, is very small. Nevertheless, these patients need to be successfully identified, appropriately advised and cautioned, and so do the surgeons that perform the procedure. CONCLUSION: When performed by an experienced multi-disciplinary team, the SLNB is a highly effective and accurate alternative to standard level I and II axillary clearance in the vast majority of patients with early breast cancer

    Heme oxygenase-1 and carbon monoxide in pulmonary medicine

    Get PDF
    Heme oxygenase-1 (HO-1), an inducible stress protein, confers cytoprotection against oxidative stress in vitro and in vivo. In addition to its physiological role in heme degradation, HO-1 may influence a number of cellular processes, including growth, inflammation, and apoptosis. By virtue of anti-inflammatory effects, HO-1 limits tissue damage in response to proinflammatory stimuli and prevents allograft rejection after transplantation. The transcriptional upregulation of HO-1 responds to many agents, such as hypoxia, bacterial lipopolysaccharide, and reactive oxygen/nitrogen species. HO-1 and its constitutively expressed isozyme, heme oxygenase-2, catalyze the rate-limiting step in the conversion of heme to its metabolites, bilirubin IXα, ferrous iron, and carbon monoxide (CO). The mechanisms by which HO-1 provides protection most likely involve its enzymatic reaction products. Remarkably, administration of CO at low concentrations can substitute for HO-1 with respect to anti-inflammatory and anti-apoptotic effects, suggesting a role for CO as a key mediator of HO-1 function. Chronic, low-level, exogenous exposure to CO from cigarette smoking contributes to the importance of CO in pulmonary medicine. The implications of the HO-1/CO system in pulmonary diseases will be discussed in this review, with an emphasis on inflammatory states

    Cobalt protoporphyrin represses osteoclastogenesis through blocking multiple signaling pathways

    Get PDF
    Cobalt protoporphyrin (CoPP) is a metallo-protoporphyrin that works as a powerful inducer of heme oxigenase-1 (HO-1) in various tissues and cells. Our recent studies have demonstrated that induction of HO-1 by several reagents inhibited differentiation and activation of osteoclasts (OCLs), which are multinucleated bone resorbing cells. However, the effects of CoPP on osteoclastogenesis remain to be elucidated. In this study, we report that CoPP inhibits receptor activator of nuclear factor κB ligand (RANKL)-induced OCL formation in a dose dependent manner. Importantly, CoPP had little cytotoxicity, but rather enhanced cell proliferation of OCLs. CoPP suppressed the protein levels of nuclear factor of activated T cells cytoplasmic-1 (NFATc1) as well as those of OCLs markers such as Src and cathepsin K, which are transcriptionally regulated by NFATc1 in mature OCLs. Western blot analyses also showed that CoPP abolished RANKL-stimulated phosphorylation of several major signaling pathways such as IκB, Akt, ERK, JNK and p38 MAPKs in OCL precursor cells. Thus, our results show that CoPP represses osteoclastogenesis through blocking multiple signaling pathways

    A comprehensive overview of radioguided surgery using gamma detection probe technology

    Get PDF
    The concept of radioguided surgery, which was first developed some 60 years ago, involves the use of a radiation detection probe system for the intraoperative detection of radionuclides. The use of gamma detection probe technology in radioguided surgery has tremendously expanded and has evolved into what is now considered an established discipline within the practice of surgery, revolutionizing the surgical management of many malignancies, including breast cancer, melanoma, and colorectal cancer, as well as the surgical management of parathyroid disease. The impact of radioguided surgery on the surgical management of cancer patients includes providing vital and real-time information to the surgeon regarding the location and extent of disease, as well as regarding the assessment of surgical resection margins. Additionally, it has allowed the surgeon to minimize the surgical invasiveness of many diagnostic and therapeutic procedures, while still maintaining maximum benefit to the cancer patient. In the current review, we have attempted to comprehensively evaluate the history, technical aspects, and clinical applications of radioguided surgery using gamma detection probe technology
    corecore